Our IP power solutions - Select the appropriate category
Our Monitoring Systems - Select the appropriate category
Our Radio Time Systems - Select the appropriate category
Choose the right accessories for our solutions
Choose your IT industry
Choose your AV area
Choose your industry
Reducing energy consumption, minimize carbon footprint - the biggest challenges of Green AV technologies
No IT without safety measures
Increased safety through out-of-band
Everything you need to know about energy monitoring
This is why energy efficiency in IT is so important
What professional environmental monitoring is all about
The right capacity planning is crucial
Flexible control through remote access
Support with basic questions
Support & Downloads for our Power Distribution Units
Support & Downloads for our Monitoring Systems
Support & Downloads for our Time Systems
Find a distributor near you
Benefit from GUDE partner status
Report your project
Read our in-depth white papers
Get to know GUDE
Meet our satisfied customers
Reach your goal faster with our well-known technology partners
All news about GUDE
Remotely switched and metered power control with 12 load outlets. The device enables switching and current measurement of connected devices whose data can be accessed via a TCP/IP network. The power switch can be used in IT infrastructures and especially in 19 inch server racks. For monitoring the environment, combined sensors (temperature, relative humidity and air pressure) can be connected to the two existing RJ45 sensor connections. Thanks to standardised protocols such as HTTP/HTTPS, Telnet, RADIUS, MQTT and Modbus TCP, the device can be controlled with a media control system or a server and can be easily integrated into a monitoring software.
On the rear of the device are 12 load outputs IEC C13 (max. 10 A), each of which can be switched separately with a switching capacity of 3.68 kW. They are combined into two independent banks with six load outputs each. These are fed by two separate IEC C20 supply lines and allow 2x 16 A or 7500 W to be switched via the unit. This enables the operation of devices with redundant power supplies. Pairwise switching of the outputs is possible, e.g. output 1 of bank 1 simultaneously with output 1 of bank 2. The outputs can be switched event-based by preset sensor thresholds.
Current peaks are prevented by automatic latency times of one second between the switching of several outputs. In addition, special high-inrush relays prevent the relay contacts from welding during inrush current peaks by withstanding currents of up to 80 A for short periods. The integrated overvoltage protection (OVP) prevents damage to the device and connected loads (L-N 10 kA).
Via bright LED displays the relevant status information and the status of the outputs (on/off) can be read directly on the device. This allows a quick overview of total current, IP addresses, sensor values and error messages.
Remote access to the device’s web server is possible via an RJ45 network connection. In addition, the power switch can be monitored and controlled while on the move via a mobile device app available free of charge. Furthermore, common security standards are supported (IPv6, SSL, SNMPv3).
The warranty period is 24 months. It is possible to extend the warranty period to 3, 4 or 5 years.
Connections • 2 power connection (IEC C20, max. 16 A, 230 V) • 2 x 6 load outputs (IEC C13, max. 10 A) • 1 RJ45 network connection (10/100 Mbit/s) • 1 serial interface RS232 (Sub-D, 9-pin) • 2 sensor inputs (RJ45) for optional sensors
Technical data • 19 inch installation: 1 HU • Dimensions (LxHxD): 43.9 x 4.4 x 19.5 cm (without rack ears) • Weight: approx. 2.9 kg • Max. current (total): 2x 16 A • Max. current (per port): 10 A • Operating temperature: 0-50 °C • Storage temperature: -20 – 70 °C • Relative humidity: 0 – 95 % (non-condensing) • High-Inrush Relay: 30 A up to 4s and 80A up to 20ms • Switching power per outlet: 3.68 kW • Overvoltage protection: L-N 10 kA
Switching function: Per load output Measuring function: Total measurement per input Measured quantities: Voltage (V), current (A), frequency (Hz), phase angle (°), active power (W), reactive power (Var), apparent power (VA), power factor (PF), energy (kWh) Display: 4-digit red LED display per bank to show total current, IP address, sensor values and error messages; plain text displays (on/off) for the status of the outputs; three LED indicators for the status of the device, power supply and OVP Supported protocols: SNMPv1, v2c, v3; HTTP, HTTPS; SSL, STARTTLS; TLS 1.1, 1.2; Syslog; TCP/IP v4, IPv6; DHCP, Telnet, Radius, Modbus TCP, MQTT 3.1.1 Housing material: Galvanized and powder coated sheet steel, black, material thickness 1.25 mm
Brand: GUDE Type: 8221-1