Our IP power solutions - Select the appropriate category
Our Monitoring Systems - Select the appropriate category
Our Radio Time Systems - Select the appropriate category
Choose the right accessories for our solutions
Choose your IT industry
Choose your AV area
Choose your industry
Reducing energy consumption, minimize carbon footprint - the biggest challenges of Green AV technologies
No IT without safety measures
Increased safety through out-of-band
Everything you need to know about energy monitoring
This is why energy efficiency in IT is so important
What professional environmental monitoring is all about
The right capacity planning is crucial
Flexible control through remote access
Support with basic questions
Support & Downloads for our Power Distribution Units
Support & Downloads for our Monitoring Systems
Support & Downloads for our Time Systems
Find a distributor near you
Benefit from GUDE partner status
Report your project
Read our in-depth white papers
Get to know GUDE
Meet our satisfied customers
Reach your goal faster with our well-known technology partners
All news about GUDE
Remotely switched and metered Power Control with 24x IEC C13 and 6x IEC C19 safety sockets for usage in combination with a media management system. The power control can be used to switch connected electrical loads on and off and for current measurement. Up to 9 electrical quantities dimensions can be measured on the input side, as well as residual current measurement (see below). Two combined sensors (temperature, humidity and air pressure) can be connected to the two RJ45 connectors for environment monitoring. Thanks to standardised protocols such as HTTP/HTTPS, Telnet, RADIUS, MQTT and Modbus TCP, the device can be controlled with a media management system, a server or integrated into a monitoring software. Connecting to Crestron and Extron devices is done quickly, thanks to available drivers.
Toolless installation in media or IT racks (19 inches), furniture, pedestals and tables is made possible because the device’s rack ears are already attached. Each output can be switched and restarted individually. The outputs can be switched event-based by pre-set sensor thresholds and programmed schedules. The switching state and switch-on delays (0…9999 seconds) are freely adjustable for each Power Port. An automated reboot can be set individually per output using the integrated watchdog function (ICMP/TCP).
The Power Control has an integrated overvoltage protection type 3. This overvoltage protection (OVP) prevents damage to the device and the connected electrical loads (max. L-N, N/L-PE 10 kA). Current peaks are prevented by automatic latency times of one second between the switching of several outputs. In addition, special high-inrush relays prevent the relay contacts from welding during inrush current peaks by withstanding currents of up to 80 A for short periods.
An easily readable LED display shows the relevant status information and the status of the outputs (on/off) directly on the device. This allows a quick overview of total current, IP address and sensor values.
Remote access to the device’s web server is possible via an RJ45 network connection and an RS232 interface. In addition, the power supply unit can be monitored and controlled while on the move via a mobile device app available free of charge. Furthermore, common security standards are supported (IPv6, SSL, SNMPv3).
Connections: – 1 power connection (IEC C20, max 16 A) – 24 load outputs (IEC C13, max 10 A) – 6 load outputs (IEC C19, max 16 A) – 1 RJ45 network connection (10/100 Mbit/s) – 2 min DIN sensor input for optional sensors
Technical data: – 19 inch installation: 0 HU – Dimensions (LxHxT): 170 x 8 x 6.5 cm – Weight: approx. approx 3.9 kg – Max. current (total): 16 A – Max. current (per port): 16 A – Power consumption: approx. 5 W – Operating temperature: 0-50 °C – Storage temperature: -20 – 70 °C – Relative humidity: 0 – 95 % (non-condensing) – High-Inrush Relay: Type 16 A, 30 A up to 4s and 80A up to 20ms – Overvoltage protection: Type 3, max. L-N, N/L-PE 10 kA
Switching function: Per load output Measuring function: Total measurement at the input of the device Measured variables: voltage (V), current (A), frequency (Hz), phase angle (°), active power (W), reactive power (Var), apparent power (VA), power factor (PF), energy (kWh), residual current measurement (mA) Display: 4-digit red LED display to show total current, IP address, sensor values and error messages; plain text displays (on/off) for the status of the outputs; three LED indicators for the status of the device, power supply and OVP Supported protocols: SNMPv1, v2c, v3; HTTP, HTTPS; SSL, STARTTLS; TLS 1.1, 1.2, 1.3; Syslog; TCP/IP v4, IPv6; DHCP, Telnet, Radius, Modbus TCP, MQTT 3.1.1
Brand: GUDE Type: 87-1310-18 Quantity: