Our IP power solutions - Select the appropriate category
Our Monitoring Systems - Select the appropriate category
Our Radio Time Systems - Select the appropriate category
Choose the right accessories for our solutions
Choose your IT industry
Choose your AV area
Choose your industry
Reducing energy consumption, minimize carbon footprint - the biggest challenges of Green AV technologies
No IT without safety measures
Increased safety through out-of-band
Everything you need to know about energy monitoring
This is why energy efficiency in IT is so important
What professional environmental monitoring is all about
The right capacity planning is crucial
Flexible control through remote access
Support with basic questions
Support & Downloads for our Power Distribution Units
Support & Downloads for our Monitoring Systems
Support & Downloads for our Time Systems
Find a distributor near you
Benefit from GUDE partner status
Report your project
Read our in-depth white papers
Get to know GUDE
Meet our satisfied customers
Reach your goal faster with our well-known technology partners
All news about GUDE
Remotely switched and metered AC/DC Power Control with 21 outlets, comprising 230V, 24V, 12V and 5V, for usage in combination with a media management system. The power control can be used to switch connected electrical loads on and off and for current measurement. Up to 9 electrical quantities dimensions can be measured on the input side, as well as residual current measurement (see below). Two combined sensors (temperature, humidity and air pressure) can be connected to the two RJ45 connectors for environment monitoring. Thanks to standardised protocols such as HTTP/HTTPS, Telnet, RADIUS, Modbus TCP and MQTT, the device can be controlled with a media management system, a server or integrated into a monitoring software. Connecting to Crestron and Extron devices is done quickly, thanks to available drivers. Toolless installation in media or IT racks (19 inches), furniture, pedestals and tables is made possible because the device’s rack ears are already attached. Each output can be switched and power-cycled individually (reboot). The outputs can be switched event-based by pre-set sensor thresholds and programmed schedules. The switching state and switch-on delays (0…9999 seconds) are freely adjustable for each Power Port. An automatic reboot can be realized per outlet thanks to the integrated watchdog (ICMP/TCP). The integrated failure-proof power supply unit (max. 300 W) with active power factor correction (PFC) has a MTBF of 1,800,000 hours. An eFuse per outlet prevents short-circuits. The Power Control disposes of an integrated overvoltage protection (SPD) type. This OVP prevents damage of the device and of connected consumers (max. L-N, L/N-PE 10 kA). Current peaks are prevented by automatic latency times of one second between the switching of several outputs. In addition, special high-inrush relays prevent the relay contacts from welding during inrush current peaks by withstanding currents of up to 80 A for short periods. An easily readable LED display shows the relevant status information and the status of the outputs (on/off) directly on the device. This allows a quick overview of total current, IP address and sensor values. Remote access to the device’s web server is possible via an RJ45 network connection and an RS232 interface. Furthermore, common security standards are supported (IPv6, SSL, SNMPv3).
Connections: • 1 power connection (IEC C20, max. 16 A), enclosed in delivery: connection cable (IEC C19 to Schuko) • 26 load outputs, of which 21 switchable, divided as follows: AC: 4 x IEC C13 cold device plug (10A) DC: 3 x 4 connection terminal (12V or 24V) 5 x connection terminal or USB A (5V) • 1 RJ45 network connection (10/100 Mbit/s) • 1 serial interface RS232 (Sub-D, 9-pin) • 2 sensor inputs (RJ45) for optional sensors
Technical data: • 19 inch installation: 1 HU • Dimensions (LxHxD): 43.9 x 4.4 x 24.1 cm (without rack ears) • Weight: approx. 4.4 kg • Max. current (total): 16A • Max. current per DC banks: 5V: max. 8,8A 12V: max. 6A 24V: max. 12,5A • Max. current per DC port: 4A • Power consumption: approx. 5W • Operating temperature: 0-50 °C • Storage temperature: -20 – 70 °C • Relative humidity: 0 – 95 % (non-condensing) • High-Inrush Relay: Type 16 A, 30 A up to 4s and 80A up to 20ms • Overvoltage protection: Type 3, max. L-N, N/L-PE 10 kA • Watchdog (ICMP/TCP) for each output • Power supply unit: with active power factor correction (PFC) and MTBF of 1,800,000 hours
Switching function: Per load output Measuring function: Total measurement at the input of the device Measured quantities: voltage (V), current (A), frequency (Hz), phase angle (°), active power (W), reactive power (Var), apparent power (VA), power factor (PF), energy (kWh), residual current measurement (mA) Display: 4-digit red LED display to show total current, IP address, sensor values and error messages; plain text displays (on/off) for the status of the outputs; three LED indicators for the status of the device, power supply and OVP Supported protocols: SNMPv1, v2c, v3; HTTP, HTTPS; SSL, STARTTLS; TLS 1.1, 1.2, 1.3; Syslog; TCP/IP v4, IPv6; DHCP, Telnet, Radius, Modbus TCP, MQTT 3.1.1
Brand: GUDE Typ: 8291-1 Menge:
Tender Spec as txt file Go to product